PLAIN TEFLON FEED-THRU

PART NO. DIMENSIONS
A B C D E F G H J K
100-1001 0.6901 0.287 12-28 UNF-2A 0.082 0.250 0.225 0.163 0.031 0.062 0.188
PART NO. DIMENSIONS
A B C D E F G H J K
100-1002 .874 0.406 12-32 UNF-2A 0.093 0.312 0.234 - 0.031 - -

Capacitance 1000 pF


RFI/EMI SUPPRESSION FILTERS

PART NO. RATED
1DC
WORKING VOLTS DCR.
MAX
REFER
CAP
INSERTION LOSS
+85°C +125°C 1
MHz
10
MHz
100
MHz
200
MHZ
1
GHz
10
GHz
100-1003 3 Amps 200 VDC 100 VDC .01 .001 MFD - 3 40 50 70 70
100-1004 10 Amps 200 VDC 100 VDC .01 .022 MFD 10 28 50 60 60 60
PART NO. RATED
1DC
WORKING VOLTS DCR.
MAX
REFER
CAP
INSERTION LOSS
+85°C +125°C 1
MHz
10
MHz
100
MHz
200
MHZ
1
GHz
10
GHz
100-1005 10 Amps 200 VDC 100 VDC .01 .0015 MFD - 3 42 60 65 65
100-1006 10 Amps 200 VDC 100 VDC .01 .022 MFD 20 30 50 55 65 65

HIGH FREQUENCY LOWPASS FEED-THRU FILTERS

PART NO. RATED
1DC
WORKING VOLTS DCR.
MAX
REFER
CAP
INSERTION LOSS
+85°C +125°C 1
MHz
10
MHz
100
MHz
200
MHZ
1
GHz
10
GHz
100-1007 10 Amps 200 VDC 100 VDC - 5500 pf - 10 50 70 70 70
PART NO. A B C D
MB50 .50 .25 .25 -
MB75 .75 .50 .37 -
MB100 1.00 .75 .50 -
MB150 1.50 1.25 .37 .75
MB200 2.00 1.75 .50 1.00
Compac Accessories Diagram Compac Accessories Diagram Compac Accessories Diagram Compac Accessories Diagram Compac Accessories Diagram Compac Accessories Diagram Compac Accessories Diagram

HOW TO ORDER:


For factory installation specifiy:

COMPAC Box #___ with Mounting Bars Installed.

For Field installation:

Select Mounting Bar 1" shorter than outside length of box

EXAMPLE: For 51220 box, use (2) MB200and (2) MB 400 bars.